LogoLogo
Pinnacle 20|20 Controls
Pinnacle 20|20 Controls
  • Pinnacle 20|20 Controls
    • Overview
    • Home Page
    • Operation
      • Control Page
      • Overview Page
      • Monitor Page
    • System Settings
      • Overview
      • Fan Settings
      • Takeaway Equipment Settings
      • Grain Fill Settings
      • Moisture Sensor Settings
      • Burner Settings
      • Discharge Speed Control
        • Manual Settings
          • Manual Settings Overview
          • Discharge Capacity
          • Incremental Speed Tables
            • 10% Discharge Speed
            • 20% Discharge Speed
            • 30% Discharge Speed
            • 40% Discharge Speed
            • 50% Discharge Speed
            • 60% Discharge Speed
            • 70% Discharge Speed
            • 80% Discharge Speed
            • 90% Discharge Speed
            • 100% Discharge Speed
          • Speed Tables (All-Heat 5pt)
          • Speed Tables (All-Heat 10pt)
          • Speed Tables (Heat+Cool 5pt)
          • Speed Tables (Heat+Cool 10pt)
          • Setting Discharge Speed Operational Limits
          • Setting Mid-Grain Temperature Alarm Limits
        • TruDry Settings
        • AccuDry Settings
          • AccuDry Technology
          • How AccuDry Works
          • Using AccuDry Mode
    • Historical Data
      • Alarm Pop-Ups and History
      • Alarm List
      • Cool Down Alarms
      • Trending
      • Data Logging History
    • Troubleshooting
      • Service
        • TruDry Settings
        • AccuDry Settings
        • Burners Settings
        • HMI Settings
      • Dryer Components
      • System Configuration
      • PLC I/O Modules
        • CPU
        • Digital Inputs / Outputs
        • Analog Inputs
        • Analog Outputs
        • Digital Inputs
        • Analog Inputs / Outputs
      • Safety Circuit
Powered by GitBook
On this page
Export as PDF
  1. Pinnacle 20|20 Controls
  2. System Settings
  3. Discharge Speed Control
  4. Manual Settings

Speed Tables (Heat+Cool 5pt)

Depending on the model dryer, the % discharge speed will correspond to an approximate bu/hr or metric tonnes/hr value for a known discharge capacity. The table below correlates discharge speed % to bu/hr based for the moisture removal (5pt or 10pt) and mode of operation (All-Heat or Heat+Cool) stated above.

Model(s)
(dry) bu/hr
tonnes/hr
Discharge Speed

L1000

700

16.3

33%

L1500

1,050

24.5

50%

L2000

1,320

30.8

63%

L3000

1,700

39.6

40%

L4000

2,280

53.1

54%

L5000

2,870

66.9

68%

L6000

3,470

80.9

82%

D600 / D600h

660

15.4

47%

D900 / D900h

1000

23.3

47%

D1200 / D1200h

1280

29.8

49%

D1500 / D1500h

1560

36.4

49%

D1800 / D1800h

1840

42.9

48%

D2100 / D2100h

2120

49.4

50%

D2400 / D2400h

2410

56.2

48%

D3200 / D3200h

3230

75.3

48%

E300

310

7.2

41%

E400

410

9.6

41%

E500

510

11.9

41%

E600

610

14.2

41%

E700h

710

16.6

40%

F320

570

13.3

41%

F320x

815

19.0

58%

F480

855

19.9

41%

F480x

1,215

28.3

58%

F660

1,155

26.9

37%

F660x

1,650

38.4

52%

10530

700

16.3

33%

10740

930

21.7

32%

10950

1,240

28.9

33%

101160

1,500

35.0

32%

101375

1,700

39.6

31%

12-20-100

2,000

46.6

47%

12-24-125

2,400

55.9

47%

12-28-150

2,800

65.3

47%

3000

3,000

69.9

50%

3500

3,500

81.6

51%

4000

4,000

93.2

53%

4800

4,800

111.9

58%