LogoLogo
Pinnacle 20|20 Controls
Pinnacle 20|20 Controls
  • Pinnacle 20|20 Controls
    • Overview
    • Home Page
    • Operation
      • Control Page
      • Overview Page
      • Monitor Page
    • System Settings
      • Overview
      • Fan Settings
      • Takeaway Equipment Settings
      • Grain Fill Settings
      • Moisture Sensor Settings
      • Burner Settings
      • Discharge Speed Control
        • Manual Settings
          • Manual Settings Overview
          • Discharge Capacity
          • Incremental Speed Tables
            • 10% Discharge Speed
            • 20% Discharge Speed
            • 30% Discharge Speed
            • 40% Discharge Speed
            • 50% Discharge Speed
            • 60% Discharge Speed
            • 70% Discharge Speed
            • 80% Discharge Speed
            • 90% Discharge Speed
            • 100% Discharge Speed
          • Speed Tables (All-Heat 5pt)
          • Speed Tables (All-Heat 10pt)
          • Speed Tables (Heat+Cool 5pt)
          • Speed Tables (Heat+Cool 10pt)
          • Setting Discharge Speed Operational Limits
          • Setting Mid-Grain Temperature Alarm Limits
        • TruDry Settings
        • AccuDry Settings
          • AccuDry Technology
          • How AccuDry Works
          • Using AccuDry Mode
    • Historical Data
      • Alarm Pop-Ups and History
      • Alarm List
      • Cool Down Alarms
      • Trending
      • Data Logging History
    • Troubleshooting
      • Service
        • TruDry Settings
        • AccuDry Settings
        • Burners Settings
        • HMI Settings
      • Dryer Components
      • System Configuration
      • PLC I/O Modules
        • CPU
        • Digital Inputs / Outputs
        • Analog Inputs
        • Analog Outputs
        • Digital Inputs
        • Analog Inputs / Outputs
      • Safety Circuit
Powered by GitBook
On this page
Export as PDF
  1. Pinnacle 20|20 Controls
  2. System Settings
  3. Discharge Speed Control
  4. Manual Settings

Speed Tables (All-Heat 5pt)

Depending on the model dryer, the % discharge speed will correspond to an approximate bu/hr or metric tonnes/hr value for a known discharge capacity. The table below correlates discharge speed % to bu/hr based for the moisture removal (5pt or 10pt) and mode of operation (All-Heat or Heat+Cool) stated above.

Model(s)
(dry) bu/hr
tonnes/hr
Discharge Speed

L1000

1,270

30.3

60%

L1500

1,830

43.7

87%

L2000

2,220

53.0

100%

L3000

3,060

73.0

73%

L4000

3,910

93.3

93%

L5000

4,770

113.8

100%

L6000

5,600

133.7

100%

D600h

1,070

25.5

76%

D900h

1,640

39.1

78%

D1200h

2,120

50.6

80%

D1500h

2,600

62.1

82%

D1800h

3,080

73.5

81%

D2100h

3,560

85.0

84%

D2400h

4,040

96.4

80%

D3200h

5,420

129.4

80%

E300 / E300h

550

13.1

73%

E400 / E400h

730

17.4

73%

E500 / E500h

910

21.7

73%

E600 / E600h

1,100

26.3

73%

E700 / E700h

1,280

30.5

73%

F320

965

23.0

69%

F320x

1,315

31.4

94%

F480

1,455

34.7

69%

F480x

1,960

46.8

93%

F660

1,960

46.8

62%

F660x

2,660

63.5

84%

Previous100% Discharge SpeedNextSpeed Tables (All-Heat 10pt)