LogoLogo
Pinnacle 20|20 Controls
Pinnacle 20|20 Controls
  • Pinnacle 20|20 Controls
    • Overview
    • Home Page
    • Operation
      • Control Page
      • Overview Page
      • Monitor Page
    • System Settings
      • Overview
      • Fan Settings
      • Takeaway Equipment Settings
      • Grain Fill Settings
      • Moisture Sensor Settings
      • Burner Settings
      • Discharge Speed Control
        • Manual Settings
          • Manual Settings Overview
          • Discharge Capacity
          • Incremental Speed Tables
            • 10% Discharge Speed
            • 20% Discharge Speed
            • 30% Discharge Speed
            • 40% Discharge Speed
            • 50% Discharge Speed
            • 60% Discharge Speed
            • 70% Discharge Speed
            • 80% Discharge Speed
            • 90% Discharge Speed
            • 100% Discharge Speed
          • Speed Tables (All-Heat 5pt)
          • Speed Tables (All-Heat 10pt)
          • Speed Tables (Heat+Cool 5pt)
          • Speed Tables (Heat+Cool 10pt)
          • Setting Discharge Speed Operational Limits
          • Setting Mid-Grain Temperature Alarm Limits
        • TruDry Settings
        • AccuDry Settings
          • AccuDry Technology
          • How AccuDry Works
          • Using AccuDry Mode
    • Historical Data
      • Alarm Pop-Ups and History
      • Alarm List
      • Cool Down Alarms
      • Trending
      • Data Logging History
    • Troubleshooting
      • Service
        • TruDry Settings
        • AccuDry Settings
        • Burners Settings
        • HMI Settings
      • Dryer Components
      • System Configuration
      • PLC I/O Modules
        • CPU
        • Digital Inputs / Outputs
        • Analog Inputs
        • Analog Outputs
        • Digital Inputs
        • Analog Inputs / Outputs
      • Safety Circuit
Powered by GitBook
On this page
Export as PDF
  1. Pinnacle 20|20 Controls
  2. System Settings
  3. Discharge Speed Control
  4. Manual Settings

Speed Tables (Heat+Cool 10pt)

Depending on the model dryer, the % discharge speed will correspond to an approximate bu/hr or metric tonnes/hr value for a known discharge capacity. The table below correlates discharge speed % to bu/hr based for the moisture removal (5pt or 10pt) and mode of operation (All-Heat or Heat+Cool) stated above.

Model(s)
(dry) bu/hr
tonnes/hr
Discharge Speed

L1000

390

9.1

18%

L1500

600

14.0

28%

L2000

750

17.5

36%

L3000

940

21.9

22%

L4000

1,300

30.3

31%

L5000

1,660

38.7

39%

L6000

2,000

46.6

47%

D600 / D600h

380

8.9

27%

D900 / D900h

580

13.5

28%

D1200 / D1200h

740

17.2

28%

D1500 / D1500h

900

21.0

28%

D1800 / D1800h

1,060

24.7

28%

D2100 / D2100h

1,220

28.4

29%

D2400 / D2400h

1,380

32.2

27%

D3200 / D3200h

1,860

43.4

28%

E300

175

4.1

23%

E400

230

5.4

23%

E500

290

6.8

23%

E600

345

8.0

23%

E700h

405

9.4

23%

F320

330

7.7

24%

F320x

475

11.1

34%

F480

490

11.4

23%

F480x

710

16.5

34%

F660

665

15.5

21%

F660x

960

22.4

30%

10530

400

9.3

19%

10740

540

12.6

18%

10950

720

16.8

19%

101160

870

20.3

19%

101375

1,000

23.3

18%

12-20-100

1,160

27.0

28%

12-24-125

1,390

32.4

27%

12-28-150

1,620

37.8

27%

3000

1,800

42.0

30%

3500

2,100

49.0

31%

4000

2,400

55.9

32%

4800

2,800

65.3

34%

PreviousSpeed Tables (Heat+Cool 5pt)NextSetting Discharge Speed Operational Limits