Modular Tower Series

The performance figures and capacities referenced herein are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. Specifications and capacities are subject ot change, with or without notice.

Dimensional Drawings

Layout drawings for different models are accessible at the links below:

10530 Layout Drawingarrow-up-right

10740 Layout Drawingarrow-up-right

10950 Layout Drawingarrow-up-right

101160 Layout Drawingarrow-up-right

101375 Layout Drawingarrow-up-right

12-20-100 Layout Drawingarrow-up-right

12-24-125 Layout Drawingarrow-up-right

12-28-150 Layout Drawingarrow-up-right

Specifications and Capacities

Models 10530 - 101160

MODELS
10530
10740
10950
101160
101375

Heat Section Holding Capacity, bu (m3)

331 (11.7)

442 (15.5)

596 (20.9)

740 (25.9)

853 (29.9)

Cool Section Holding Capacity, bu (m3)

111 (3.9)

176 (6.2)

199 (7.0)

232 (8.1)

296 (10.4)

Wet Hopper Holding Capacity, bu (m3)

140 (4.9)

140 (4.9)

140 (4.9)

140 (4.9)

140 (4.9)

Total Holding Capacity, bu (m3)

582 (20.5)

758 (26.5)

935 (32.7)

1,112 (38.9)

1,289 (45.1)

Total Height, (m)1

34'-4" (10.5)

42'-5" (12.9)

50'-6" (15.4)

58'-6" (17.8)

66'-7" (20.3)

Fill Height, (m)1

32'-4" (9.9)

40'-5" (12.3)

48'-5" (14.8)

56'-6" (17.2)

64'-7" (19.7)

Diameter, (m)

9'-9" (3.0)

9'-9" (3.0)

9'-9" (3.0)

9'-9" (3.0)

9'-9" (3.0)

Grain Column Thickness, (cm)

12" (30.5)

12" (30.5)

12" (30.5)

12" (30.5)

12" (30.5)

Number of External Walkways

1

1

2

3

3

Grain Exchanger

N/A

N/A

Optional

Optional

Optional

Average Operating Burner Capacity, MMBTU/hr (kW thermal)2

3.37 (988)

4.41 (1,289)

5.96 (1,742)

7.26 (2,122)

8.16 (2,391)

Max Operating Burner Capacity, MMBTU/hr (kW thermal)3

4.49 (1,316)

5.88 (1,718)

7.95 (2,323)

9.68 (2,829)

10.89 (3,183)

Max Nameplate Burner Capacity, MMBTU/hr (kW thermal)

9.00 (2,638)

10.00 (2,931)

11.00 (3,224)

12.50 (3,663)

12.50 (3,663)

3-ph Electrical Full Load Amps 230V / 460V 208V / 575V (380V)

106 / 53 117 / 42 (64)

136 / 68 150 / 54 (82)

166 / 83 184 / 67 (100)

190 / 95 209 / 76 (116)

228 / 114 253 / 91 (140)

Fan Airflow, CFM (m3/hr)

26,700 (45,363)

35,100 (59,636)

47,200 (80,194)

59,500 (101,092)

64,700 (109,927)

Number of Fans

1

1

1

1

1

Fan Motor Size, HP (kW)

30 (22.4)

40 (29.8)

50 (37.3)

60 (44.7)

75 (55.9)

Capacity, Shelled Corn, 20%-15%4 wet bushels/hr (metric tonnes/hr)5 dry bushels/hr (metric tonnes/hr)5

up to 745 (18.4) 700 (16.3)

up to 990 (24.5) 930 (21.7)

up to 1,320 (32.7) 1,240 (28.9)

up to 1,595 (39.5) 1,500 (35.0)

up to 1,810 (44.8) 1,700 (39.6)

Capacity, Shelled Corn, 25%-15%4 wet bushels/hr (metric tonnes/hr)5 dry bushels/hr (metric tonnes/hr)5

up to 455 (12.0) 400 (9.3)

up to 615 (16.2) 540 (12.6)

up to 820 (21.6) 720 (16.8)

up to 990 (26.1) 870 (20.3)

up to 1,135 (29.9) 1,000 (23.3)

Models 12-20-100 - 12-28-150

MODELS
12-20-100
12-24-125
12-28-150

Heat Section Holding Capacity, bu (m3)

1,024 (36.0)

1,293 (45.4)

1,535 (53.9)

Cool Section Holding Capacity, bu (m3)

391 (13.7)

444 (15.6)

525 (18.4)

Wet Hopper Holding Capacity, bu (m3)

335 (11.8)

335 (11.8)

335 (11.8)

Total Holding Capacity, bu (m3)

1,750 (61.5)

2,072 (72.8)

2,395 (84.1)

Total Height, (m)1

74'-11" (22.8)

87'-0" (26.5)

99'-2" (30.2)

Fill Height, (m)1

71'-11" (21.9)

84'-0" (25.6)

96'-2" (29.3)

Diameter, (m)

11'-8" (3.6)

11'-8" (3.6)

11'-8" (3.6)

Grain Column Thickness, (cm)

12" (30.5)

12" (30.5)

12" (30.5)

Number of External Walkways

3

4

5

Grain Exchanger

Optional

Optional

Optional

Average Operating Burner Capacity, MMBTU/hr (kW thermal)2

11.70 (3,429)

14.20 (4,162)

16.50 (4,836)

Max Operating Burner Capacity, MMBTU/hr (kW thermal)3

15.70 (4,601)

18.90 (5,539)

22.10 (6,477)

Max Nameplate Burner Capacity, MMBTU/hr (kW thermal)

25.00 (7,327)

27.00 (7,913)

27.00 (7,913)

3-ph Electrical Full Load Amps 230V / 460V 208V / 575V (380V)

296 / 148 327 / 118 (180)

366 / 183 404 / 146 (221)

444 / 222 N/A / 177 (268)

Fan Airflow, CFM (m3/hr)

90,000 (152,912)

109,000 (185,193)

128,000 (217,474)

Number of Fans

1

1

1

Fan Motor Size, HP (kW)

100 (74.6)

125 (93.2)

150 (112)

Capacity, Shelled Corn, 20%-15%4 wet bushels/hr (metric tonnes/hr)5 dry bushels/hr (metric tonnes/hr)5

up to 2,125 (52.6) 2,000 (46.6)

up to 2,550 (63.1) 2,400 (55.9)

up to 2,980 (73.8) 2,800 (65.3)

Capacity, Shelled Corn, 25%-15%4 wet bushels/hr (metric tonnes/hr)5 dry bushels/hr (metric tonnes/hr)5

up to 1,315 (34.7) 1,160 (27.0)

up to 1,575 (41.6) 1,390 (32.4)

up to 1,840 (48.5) 1,620 (37.8)

1Grain exchanger option adds 3'-0" (.91m) to models 10950 - 101375 and 4'-0" (1.22m) to models 12-20-100 - 12-28-150. 2Average burner capacities based on 150 deg F (83 deg C) temperature rise and 20% reclamation efficiency. 3Max burner capacities based on 200 deg F (111 deg C) temperature rise and 20% reclamation efficiency. 4The information contained in this brochure is intended to assist our customers in selecting the grain drying system that they believe best meets their unique preferences and needs. The performance figures and capacities presented in this brochure are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. 5Capacities in metric tonnes/hr are based on a grain bulk density of: 749 kg/m3 (wet @ 25% moisture), 703 kg/m3 (wet @ 20% moisture), 661 kg/m3 (dry @ 15% moisture).

Last updated