Commercial Tower Series
The performance figures and capacities referenced herein are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. Specifications and capacities are subject ot change, with or without notice.
Dimensional Drawings
Layout drawings for different models are accessible at the links below:
Specifications and Capacities
Heat Section Holding Capacity, bu (m3)
2,092 (73.4)
2,343 (82.2)
2,594 (91.0)
2,888 (101.3)
Cool Section Holding Capacity, bu (m3)
700 (24.6)
700 (24.6)
826 (29.0)
826 (29.0)
Additional Holding Capacity, bu (m3)
919 (32.2)
919 (32.2)
919 (32.2)
919 (32.2)
Total Height, (m)
85'-3" (26.0)
91'-3" (27.8)
100'-3" (30.6)
106'-3" (32.4)
Fill Height, (m)
83'-5" (25.4)
89'-5" (27.3)
98'-5" (30.0)
104'-5" (31.8)
Diameter, (m)
17'-6" (5.3)
17'-6" (5.3)
17'-6" (5.3)
17'-6" (5.3)
Grain Column Thickness, (cm)
12" (30.5)
12" (30.5)
12" (30.5)
12" (30.5)
Number of External Walkways
2
3
3
3
Max Burner Capacity, MMBTU/hr (kW thermal)
33.7 (9,849)
36.3 (10,609)
42.5 (12,421)
44.2 (12,919)
Average Burner Capacity, MMBTU/hr (kW thermal)
20.2 (5,904)
21.8 (6,371)
25.5 (7,453)
26.5 (7,745)
3-ph Electrical Full Load Amps 230V / 460V 208V / 575V (380V)
393 / 197 436 / 158 (237)
455 / 227 501 / 181 (277)
555 / 278 615 / 223 (340)
555 / 278 615 / 223 (340)
Fan(s) Total Airflow, CFM (m3/hr)
153,000 (259,947)
156,000 (265,044)
193,000 (327,907)
200,000 (339,800)
Number of Fans
3
3
3
3
Fan Motor(s) Size, HP (kW)
3 x 50 (3 x 37.3)
3 x 60 (3 x 44.7)
3 x 75 (3 x 55.9)
3 x 75 (3 x 55.9)
Capacity, Shelled Corn, 20%-15%1 wet bushels/hr (metric tonnes/hr)2 dry bushels/hr (metric tonnes/hr)2
up to 3,190 (79.0) 3,000 (69.9)
up to 3,720 (92.1) 3,500 (81.6)
up to 4,250 (105.2) 4,000 (93.2)
up to 5,100 (126.2) 4,800 (111.9)
Capacity, Shelled Corn, 25%-15%1 wet bushels/hr (metric tonnes/hr)2 dry bushels/hr (metric tonnes/hr)2
up to 2,040 (53.8) 1,800 (42.0)
up to 2,380 (62.8) 2,100 (49.0)
up to 2,720 (71.8) 2,400 (55.9)
up to 3,175 (83.8) 2,800 (65.3)
1The information contained in this brochure is intended to assist our customers in selecting the grain drying system that they believe best meets their unique preferences and needs. The performance figures and capacities presented in this brochure are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. 2Capacities in metric tonnes/hr are based on a grain bulk density of: 749 kg/m3 (wet @ 25% moisture), 703 kg/m3 (wet @ 20% moisture), 661 kg/m3 (dry @ 15% moisture).