Delta Series

The performance figures and capacities referenced herein are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. Specifications and capacities are subject to change, with or without notice.

Dimensional Drawings

Layout drawings for different models are accessible at the links below:

D600 / D600h Layout Drawing

D900 / D900h Layout Drawing

D1200 / D1200h Layout Drawing

D1500 / D1500h Layout Drawing

D1800 / D1800h Layout Drawing

D2100 / D2100h Layout Drawing

D2400 / D2400h Layout Drawing

D3200 / D3200h Layout Drawing

Specifications and Capacities

Models D600 / D600h - D1500 / D1500h

SPECIFICATIONS
D600 / h
D900 / h
D1200 / h
D1500 / h

Holding, Top + Bottom Drying Section, bu (m3)

743 + 276 (26.2 + 9.7)

1,112 + 413 (39.2 + 14.6)

1,453 + 584 (51.2 + 20.6)

1,794 + 754 (63.2 + 26.6)

Additional Holding - Gravity Fill / Level Auger, bu (m3)

227 / 215 (8.0 / 7.6)

404 / 321 (14.2 / 11.3)

404 / 321 (14.2 / 11.3)

404 / 321 (14.2 / 11.3)

Total Holding - Gravity Fill / Level Auger, bu (m3)

1,247 / 1,235 (43.9 / 43.5)

1,929 / 1,847 (68.0 / 65.1)

2,440 / 2,358 (86.0 / 83.1)

2,952 / 2,870 (104.0 / 101.1)

Tier Length, (m)

16'-0" (4.9)

24'-0" (7.3)

24'-0" (7.3)

24'-0" (7.3)

Top Fan, HP (kW) Bottom Fan, HP (kW)

2 x 15 (11.2) 10 (7.5)

2 x 20 (14.9) 10 (7.5)

2 x 25 (18.6) 15 (11.2)

2 x 30 (22.4) 25 (18.6)

Number of Tiers

9

9

12

15

Fill Height - Gravity Fill / Level Auger, (m)1

29'-10" / 27'-5" (9.1 / 8.4)

32'-10" / 27'-5" (10.0 / 8.4)

38'-10" / 33'-5" (11.8 / 10.2)

44'-10" / 39'-5" (13.7 / 12.0)

ALL-HEAT MODE
D600 / h
D900 / h
D1200 / h
D1500 / h

Avg / Max Burner Operating, MMBTU/hr (kW thermal)2,6

7.2 / 9.6 (2,110 / 2,814)

10.8 / 14.4 (3,170 / 4,227)

14.3 / 19.1 (4,192 / 5,589)

17.8 / 23.7 (5,208 / 6,944)

Drying Capacity, Shelled Corn, 20%-15%3,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 1,110 (27.5) 1,070 (25.5)

up to 1,700 (42.1) 1,640 (39.1)

up to 2,200 (54.5) 2,120 (50.6)

up to 2,690 (66.6) 2,600 (62.1)

Drying Capacity, Shelled Corn, 25%-15%3,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 580 (15.3) 520 (12.4)

up to 880 (23.2) 790 (18.9)

up to 1,140 (30.1) 1,030 (24.6)

up to 1,390 (36.7) 1,260 (30.1)

HEAT + COOL MODE
D600 / h
D900 / h
D1200 / h
D1500 / h

Avg / Max Burner Operating, MMBTU/hr (kW thermal)2,6

5.3 / 7.1 (1,559 / 2,078)

8.0 / 10.7 (2,343 / 3,124)

10.3 / 13.7 (3,011 / 4,014)

12.6 / 16.7 (3,679 / 4,905)

Drying Capacity, Shelled Corn, 20%-15%3,4,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 700 (17.3) 660 (15.4)

up to 1,060 (26.2) 1,000 (23.3)

up to 1,360 (33.7) 1,280 (29.8)

up to 1,660 (41.1) 1,560 (36.4)

Shelled Corn, 25%-15%3,4,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 430 (11.3) 380 (8.9)

up to 660 (17.4) 580 (13.5)

up to 840 (22.2) 740 (17.2)

up to 1,020 (26.9) 900 (21.0)

Models D1800 / D1800h - D3200 / D3200h

SPECIFICATIONS
D1800 / h
D2100 / h
D2400 / h
D3200 / h

Holding, Top + Bottom Drying Section, bu (m3)

2,135 + 925 (75.2 + 32.6)

2,476 + 1,095 (87.3 + 38.6)

2,817 + 1,266 (99.3 + 44.6)

3,751 + 1,685 (132.2 + 59.4)

Additional Holding - Gravity Fill / Level Auger, bu (m3)

404 / 321 (14.2 / 11.3)

404 / 321 (14.2 / 11.3)

404 / 321 (14.2 / 11.3)

622 / 428 (21.9 / 15.1)

Total Holding - Gravity Fill / Level Auger, bu (m3)

3,464 / 3,381 (122.1 / 119.2)

3,975 / 3,893 (140.1 / 137.2)

4,487 / 4,405 (158.1 / 155.2)

6,059 / 5,864 (213.5 / 206.7)

Tier Length, (m)

24'-0" (7.3)

24'-0" (7.3)

24'-0" (7.3)

32'-0" (9.8)

Top Fan, HP (kW) Bottom Fan, HP (kW)

2 x 40 (29.8) 30 (22.4)

2 x 40 (29.8) 40 (29.8)

2 x 50 (37.3) 50 (37.3)

2 x 60 (44.7) 60 (44.7)

Number of Tiers

18

21

24

32

Fill Height - Gravity Fill / Level Auger, (m)1

50'-10" / 45'-5" (15.5 / 13.8)

56'-10" / 51'-5" (17.3 / 15.7)

62'-10" / 57'-5" (19.2 / 17.5)

65'-10" / 57'-5" (20.1 / 17.5)

ALL-HEAT MODE
D1800 / h
D2100 / h
D2400 / h
D3200 / h

Avg / Max Burner Operating, MMBTU/hr (kW thermal)2,6

21.2 / 28.3 (6,220 / 8,293)

24.7 / 32.9 (7,231 / 9,642)

28.1 / 37.5 (8,248 / 10,997)

37.5 / 50.0 (10,997 / 14,663)

Drying Capacity, Shelled Corn, 20%-15%3,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 3,190 (79.0) 3,080 (73.5)

up to 3,690 (91.3) 3,560 (85.0)

up to 4,190 (103.7) 4,040 (96.4)

up to 5,630 (139.4) 5,420 (129.4)

Drying Capacity, Shelled Corn, 25%-15%3,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 1,650 (43.5) 1,490 (35.6)

up to 1,900 (50.1) 1,720 (41.1)

up to 2,160 (57.0) 1,950 (46.5)

up to 2,900 (76.5) 2,620 (62.5)

HEAT + COOL MODE
D1800 / h
D2100 / h
D2400 / h
D3200 / h

Avg / Max Burner Operating, MMBTU/hr (kW thermal)2,6

14.8 / 19.7 (4,337 / 5,783)

17.1 / 22.8 (5,005 / 6,673)

19.4 / 25.8 (5,673 / 7,564)

25.8 / 34.4 (7,561 / 10,081)

Drying Capacity, Shelled Corn, 20%-15%3,4,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 1,960 (48.5) 1,840 (42.9)

up to 2,260 (55.9) 2,120 (49.4)

up to 2,560 (63.4) 2,410 (56.2)

up to 3,430 (84.9) 3,230 (75.3)

Shelled Corn, 25%-15%3,4,5,6 wet bu/hr (metric tonnes/hr) dry bu/hr (metric tonnes/hr)

up to 1,200 (31.7) 1,060 (24.7)

up to 1,390 (36.7) 1,220 (28.4)

up to 1,570 (41.4) 1,380 (32.2)

up to 2,100 (55.4) 1,860 (43.4)

1Add 24" (.61m) for a 24" dryer stand set, 36" (.92m) for a 36" dryer stand set, or 48" (1.22m) for a 48" dryer stand set. 2Operating burner capacities are based on a 150 deg F (83 deg C) temperature rise for average and 200 deg F (111 deg C) temperature rise for maximum. 3Based on 240 deg F (116 deg C) plenum temperature for heat + cool operation, and 240 deg F (116 deg C) top plenum temperature / 180 deg F (82 deg C) bottom plenum temperature for all-heat operation. 4Based on discharging grain from the dryer at 17.0% moisture. 5Capacities in metric tonnes/hr are based on a grain bulk density of: 749 kg/m3 (wet @ 25% moisture), 703 kg/m3 (wet @ 20% moisture), 677 kg/m3 (dry @ 17% moisture), 661 kg/m3 (dry @ 15% moisture). 6The information contained herein is intended to assist our customers in selecting the grain drying system that they believe best meets their unique preferences and needs. The performance figures and capacities presented in this document are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation.