LogoLogo
Dryer Operations
Dryer Operations
  • Dryer Operations
    • Applicability
    • Introduction
    • Warranty
    • CSA 3.8 2021
    • Specifications
      • Delta Series
      • Fusion Series
      • ECO Series
      • Legacy Series
      • Modular Tower Series
      • Commercial Tower Series
    • Equipment Overview
      • Main Dryer Components
      • High Voltage Cabinet
      • Low Voltage Cabinet
      • Pinnacle 20|20 Remote Cabinet
      • Customer Equipment Cabinet
      • Burner Control Cabinet
      • Discharge Moisture Sampler
      • Gas Train
      • Burner
    • Operating Procedures
      • Component Adjustments
      • Air Pressure Switch
      • High Limit Switch
      • VFD (Parameters)
        • Profile & Mixed-Flow Models
        • Modular Towers (208/230/460V)
        • Modular Towers (380/575V)
        • Commercial Towers (208/230/460V)
      • Soft Start (Parameters)
      • Fireye Burner Control
      • First Time Start-Up
      • Daily Operations
      • End-of-Season Shut-Down
      • Suggested Operating Setpoints
    • Maintenance
      • Pre-Season Checks
      • Lubrication Schedule
      • Seasonal Cleaning
      • Post-Season Maintenance
    • Troubleshooting
      • Diagnosing a Dryer Shutdown
      • Diagnosing Safety Circuit via HMI
      • Diagnosing the Safety Circuit Using a Voltmeter
      • Emergency Stops
      • Customer Interface
      • Variable Frequency Drives
      • Soft Starters
      • Common Diagnostic Issues
Powered by GitBook
On this page
  • Moisture Sensor
  • Discharge Limit Switch
  • Moisture Sampler Auger Motor
Export as PDF
  1. Dryer Operations
  2. Equipment Overview

Discharge Moisture Sampler

PreviousBurner Control CabinetNextGas Train

Last updated 7 months ago

The discharge moisture sampler is used to continuously collect a sample of grain, move it past the discharge moisture sensor in a controlled and steady fashion, and return the sampled grain back to the discharge of the dryer.

Moisture Sensor

The Moisture Sensor is an electronic device that measures the grain moisture indirectly by measuring the capacitance of the field of grain and correlating it to a voltage. Additionally, there is a small thermistor, which also produces an analog output voltage, mounted on the face of the sensor to measure the grain's temperature to compensate the moisture reading and to provide a real-time indication of the grain's temperatures. These voltages are input to the PLC and when calibrated, will display the discharge grain moisture as well as the temperature on the HMI touchscreens.

Discharge Limit Switch

The Discharge Limit Switch is a spring-loaded lever that maintains a normally open contact which is held closed. The purpose of this switch is to detect a discharge grain overload condition that may be a result of a failed discharge auger or takeaway equipment. Once an overload condition exists, the top door on the discharge auger will lift up and the switch will return to its normally open position; in doing so, the safety circuit is opened and the dryer is shutdown.

Moisture Sampler Auger Motor

The Moisture Sampler Auger Motor is a small fractional HP motor that slowly augers a sample of grain past the moisture sensor and returns the sampled grain back to the primary discharge of the dryer.

Tower Sampler shown on left, Profile Sampler on shown on right