# ECO Series

The performance figures and capacities referenced herein are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. Specifications and capacities are subject ot change, with or without notice.

## Dimensional Drawings

Layout drawings for different models are accessible at the links below:

[E300 / E300h Layout Drawing](https://drive.google.com/file/d/1r77zcZRloz-0BLi90lXK_HwaDkKVBp5e/view?usp=drive_link)

[E400 / E400h Layout Drawing](https://drive.google.com/file/d/1IXWWLT7axVOd_UKFjaUkZtL-BOn7vY_F/view?usp=drive_link)

[E500 / E500h Layout Drawing](https://drive.google.com/file/d/1nbrmk03Y-Wxa5wAGb_pjARjceI0R-1O3/view?usp=drive_link)

[E600 / E600h Layout Drawing](https://drive.google.com/file/d/1MdS-YeIMaDNUF0eeBXGI6ehf5hb8BvRt/view?usp=drive_link)

[E700 / E700h Layout Drawing](https://drive.google.com/file/d/1tRFczUMaSf1tfEpSNTe0mJuwR72_XPwW/view?usp=drive_link)

## Specifications and Capacities

<table data-full-width="true"><thead><tr><th width="235">MODELS (Note 1)</th><th align="center">E300 / h</th><th align="center">E400 / h</th><th align="center">E500 / h</th><th align="center">E600 / h</th><th align="center">E700 / h</th></tr></thead><tbody><tr><td> Dryer Holding + Additional Holding = Total Holding Capacity, bu (m<sup>3</sup>)</td><td align="center">205 + 95 = 300<br>(7.2 + 3.3 = 10.5)</td><td align="center">275 + 125 = 400<br>(9.7 + 4.4 = 14.1)</td><td align="center">345 + 155 = 500<br>(12.2 + 5.5 = 17.7)</td><td align="center">415 + 185 = 600<br>(14.6 + 6.5 = 21.1)</td><td align="center">485 + 215 = 700<br>(17.1 + 7.6 = 24.7)</td></tr><tr><td> Grain Column Thickness, (cm)</td><td align="center">14” (35.6)</td><td align="center">14” (35.6)</td><td align="center">14” (35.6)</td><td align="center">14” (35.6)</td><td align="center">14” (35.6)</td></tr><tr><td> Overall Height<sup>2</sup> / Width, (m)</td><td align="center">15’-3” (4.6) / 7’-4” (2.2)</td><td align="center">15’-3” (4.6) / 7’-4” (2.2)</td><td align="center">15’-3” (4.6) / 7’-4” (2.2)</td><td align="center">15’-3” (4.6) / 7’-4” (2.2)</td><td align="center">15’-3” (4.6) / 7’-4” (2.2)</td></tr><tr><td> Grain Column / Overall Length<sup>3</sup>, (m)</td><td align="center">12’-0” (3.7) / 21’-6” (6.6)</td><td align="center">16’-0” (4.9) / 25’-6” (7.8)</td><td align="center">20’-0” (6.1) / 31’-7” (9.6)</td><td align="center">24’-0” (7.3) / 35’-7” (10.8)</td><td align="center">28’-0” (8.5) / 39’-7” (12.1)</td></tr><tr><td> Level Auger Motor Size, HP (kW)</td><td align="center">3 (2.2)</td><td align="center">3 (2.2)</td><td align="center">3 (2.2)</td><td align="center">3 (2.2)</td><td align="center">3 (2.2)</td></tr><tr><td> Unload Auger Motor Size, HP (kW)</td><td align="center">1.5 (1.1)</td><td align="center">1.5 (1.1)</td><td align="center">1.5 (1.1)</td><td align="center">1.5 (1.1)</td><td align="center">2 (1.5)</td></tr><tr><td> Number of Fans</td><td align="center">1 Centrifugal Fan</td><td align="center">1 Centrifugal Fan</td><td align="center">1 Centrifugal Fan</td><td align="center">1 Centrifugal Fan</td><td align="center">1 Centrifugal Fan</td></tr><tr><td> 3-ph Fan Motor Size, HP (kW)</td><td align="center">15 (11.2)</td><td align="center">20 (14.9)</td><td align="center">25 (18.6)</td><td align="center">30 (22.4)</td><td align="center">40 (29.8)</td></tr><tr><td> 3-ph Electrical Full Load Amps,<br>208V / 230V / 460V / 575V (380V)</td><td align="center">80 / 74 / 36 / 37<br>(42)</td><td align="center">97 / 89 / 43 / 43<br>(52)</td><td align="center">112 / 102 / 50 / 48<br>(59)</td><td align="center">127 / 116 / 57 / 54<br>(68)</td><td align="center">160 / 146 / 72 / 66<br>(86)</td></tr><tr><td>1-ph Fan Motor Size, HP (kW)</td><td align="center">1 x 15 (11.2)</td><td align="center">2 x 10 (7.5)</td><td align="center">2 x 15 (14.9)</td><td align="center">2 x 15 (14.9)</td><td align="center">N/A</td></tr><tr><td>1-ph Electrical Full Load Amps, 230V</td><td align="center">118</td><td align="center">131</td><td align="center">180</td><td align="center">180</td><td align="center">N/A</td></tr></tbody></table>

<table data-full-width="true"><thead><tr><th width="235">ALL-HEAT MODE</th><th align="center">E300 / h</th><th align="center">E400 / h</th><th align="center">E500 / h</th><th align="center">E600 / h</th><th align="center">E700 / h</th></tr></thead><tbody><tr><td> Avg / Max Operating Burner Capacity,<br>MMBTU/hr (kW thermal)<sup>4</sup></td><td align="center">2.92 / 3.89<br>(856 / 1,140)</td><td align="center">3.89 / 5.18<br>(1,140 / 1,518)</td><td align="center">4.86 / 6.48<br>(1,424 / 1,899)</td><td align="center">5.83 / 7.78<br>(1,709 / 2,280)</td><td align="center">6.77 / 9.02<br>(1,984 / 2,643)</td></tr><tr><td> Capacity, Shelled Corn, 20%-15%<sup>5,6,7,8</sup><br>wet bushels/hr (wet metric tonnes/hr)<br>dry bushels/hr (dry metric tonnes/hr)</td><td align="center">up to<br>575 (14.2)<br>550 (13.1)</td><td align="center">up to<br>760 (18.8)<br>730 (17.4)</td><td align="center">up to<br>945 (23.4)<br>910 (21.7)</td><td align="center">up to<br>1,145 (28.3)<br>1,100 (26.3)</td><td align="center">up to<br>1,330 (32.9)<br>1,280 (30.5)</td></tr><tr><td> Capacity, Shelled Corn, 25%-15%<sup>5,6,7,8</sup><br>wet bushels/hr (metric tonnes/hr)<br>dry bushels/hr (metric tonnes/hr)</td><td align="center">up to<br>300 (7.9)<br>270 (6.4)</td><td align="center">up to<br>400 (10.6)<br>360 (8.6)</td><td align="center">up to<br>495 (13.1)<br>445 (10.6)</td><td align="center">up to<br>595 (15.7)<br>535 (12.8)</td><td align="center">up to<br>690 (18.2)<br>625 (14.9)</td></tr></tbody></table>

<table data-full-width="true"><thead><tr><th width="235">HEAT + COOL MODE</th><th align="center">E300</th><th align="center">E400</th><th align="center">E500</th><th align="center">E600</th><th align="center">E700</th></tr></thead><tbody><tr><td> Avg / Max Operating Burner Capacity,<br>MMBTU/hr (kW thermal)<sup>4</sup></td><td align="center">1.99 / 2.65<br>(583 / 777)</td><td align="center">2.65 / 3.53<br>(777 / 1,035)</td><td align="center">3.24 / 4.32<br>(950 / 1,266)</td><td align="center">3.89 / 5.18<br>(1,140 / 1,518)</td><td align="center">4.51 / 6.02<br>(1,322 / 1,765)</td></tr><tr><td> Capacity, Shelled Corn, 20%-15%<sup>5,7,8</sup><br>wet bushels/hr (metric tonnes/hr)<br>dry bushels/hr (metric tonnes/hr)</td><td align="center">up to<br>330 (8.2)<br>310 (7.2)</td><td align="center">up to<br>435 (10.8)<br>410 (9.6)</td><td align="center">up to<br>540 (13.4)<br>510 (11.9)</td><td align="center">up to<br>650 (16.1)<br>610 (14.2)</td><td align="center">up to<br>755 (18.7)<br>710 (16.6)</td></tr><tr><td> Capacity, Shelled Corn, 25%-15%<sup>5,7,8</sup><br>wet bushels/hr (metric tonnes/hr)<br>dry bushels/hr (metric tonnes/hr)</td><td align="center">up to<br>200 (5.3)<br>175 (4.1)</td><td align="center">up to<br>260 (6.9)<br>230 (5.4)</td><td align="center">up to<br>330 (8.7)<br>290 (6.8)</td><td align="center">up to<br>390 (10.3)<br>345 (8.0)</td><td align="center">up to<br>460 (12.1)<br>405 (9.4)</td></tr></tbody></table>

<sup>1</sup>1Dryer models can be configured as heat + cool or all-heat (E300, E400, E500, E600, E700) or all-heat only (E300h, E400h, E500h, E600h, E700h).\ <sup>2</sup>Add 24” (.61m) for a 24" dryer stand set or 36” (.92m) for a 36" dryer stand set.\ <sup>3</sup>Add 1’-0”(.30m) if remote cabinet is mounted to the dryer.\ <sup>4</sup>Operating burner capacities are based on a 150 deg F (83 deg C) temperature rise for average and 200 deg F (111 deg C) temperature rise for maximum.\ <sup>5</sup>Based on 220 deg F (104 deg C) heat plenum(s) temperature.\ <sup>6</sup>Discharging at 17% moisture.\ <sup>7</sup>Capacities in metric tonnes/hr are based on a grain bulk density of: 749 kg/m3 (wet @ 25% moisture), 703 kg/m3 (wet @ 20% moisture), 677 kg/m3 (dry @ 17% moisture), 661 kg/m3 (dry @ 15% moisture).\ <sup>8</sup>The information contained herein is intended to assist our customers in selecting the grain drying system that they believe best meets their unique preferences and needs. The performance figures and capacities presented in this document are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation.