The performance figures and capacities referenced herein are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation. Specifications and capacities are subject ot change, with or without notice.
Layout drawings for different models are accessible at the links below:
11Dryer models can be configured as heat + cool or all-heat (E300, E400, E500, E600, E700) or all-heat only (E300h, E400h, E500h, E600h, E700h). 2Add 24β (.61m) for a 24" dryer stand set or 36β (.92m) for a 36" dryer stand set. 3Add 1β-0β(.30m) if remote cabinet is mounted to the dryer. 4Operating burner capacities are based on a 150 deg F (83 deg C) temperature rise for average and 200 deg F (111 deg C) temperature rise for maximum. 5Based on 220 deg F (104 deg C) heat plenum(s) temperature. 6Discharging at 17% moisture. 7Capacities in metric tonnes/hr are based on a grain bulk density of: 749 kg/m3 (wet @ 25% moisture), 703 kg/m3 (wet @ 20% moisture), 677 kg/m3 (dry @ 17% moisture), 661 kg/m3 (dry @ 15% moisture). 8The information contained herein is intended to assist our customers in selecting the grain drying system that they believe best meets their unique preferences and needs. The performance figures and capacities presented in this document are only estimates, based on calculated simulations, and do not constitute express or implied warranties. Many factors influence the grain drying process, including ambient temperature, relative humidity, grain variety, grain quality, grain temperature, dryer operating temperatures, dryer add-ons and accessories, and dryer condition, maintenance and operation.
14β (35.6)
14β (35.6)
Overall Height2 / Width, (m)
15β-3β (4.6) / 7β-4β (2.2)
15β-3β (4.6) / 7β-4β (2.2)
15β-3β (4.6) / 7β-4β (2.2)
15β-3β (4.6) / 7β-4β (2.2)
15β-3β (4.6) / 7β-4β (2.2)
Grain Column / Overall Length3, (m)
12β-0β (3.7) / 21β-6β (6.6)
16β-0β (4.9) / 25β-6β (7.8)
20β-0β (6.1) / 31β-7β (9.6)
24β-0β (7.3) / 35β-7β (10.8)
28β-0β (8.5) / 39β-7β (12.1)
Level Auger Motor Size, HP (kW)
3 (2.2)
3 (2.2)
3 (2.2)
3 (2.2)
3 (2.2)
Unload Auger Motor Size, HP (kW)
1.5 (1.1)
1.5 (1.1)
1.5 (1.1)
1.5 (1.1)
2 (1.5)
Number of Fans
1 Centrifugal Fan
1 Centrifugal Fan
1 Centrifugal Fan
1 Centrifugal Fan
1 Centrifugal Fan
3-ph Fan Motor Size, HP (kW)
15 (11.2)
20 (14.9)
25 (18.6)
30 (22.4)
40 (29.8)
3-ph Electrical Full Load Amps, 208V / 230V / 460V / 575V (380V)
80 / 74 / 36 / 37 (42)
97 / 89 / 43 / 43 (52)
112 / 102 / 50 / 48 (59)
127 / 116 / 57 / 54 (68)
160 / 146 / 72 / 66 (86)
1-ph Fan Motor Size, HP (kW)
1 x 15 (11.2)
2 x 10 (7.5)
2 x 15 (14.9)
2 x 15 (14.9)
N/A
1-ph Electrical Full Load Amps, 230V
118
131
180
180
N/A
up to 1,145 (28.3) 1,100 (26.3)
up to 1,330 (32.9) 1,280 (30.5)
Capacity, Shelled Corn, 25%-15%5,6,7,8 wet bushels/hr (metric tonnes/hr) dry bushels/hr (metric tonnes/hr)
up to 300 (7.9) 270 (6.4)
up to 400 (10.6) 360 (8.6)
up to 495 (13.1) 445 (10.6)
up to 595 (15.7) 535 (12.8)
up to 690 (18.2) 625 (14.9)
up to 650 (16.1) 610 (14.2)
up to 755 (18.7) 710 (16.6)
Capacity, Shelled Corn, 25%-15%5,7,8 wet bushels/hr (metric tonnes/hr) dry bushels/hr (metric tonnes/hr)
up to 200 (5.3) 175 (4.1)
up to 260 (6.9) 230 (5.4)
up to 330 (8.7) 290 (6.8)
up to 390 (10.3) 345 (8.0)
up to 460 (12.1) 405 (9.4)
Dryer Holding + Additional Holding = Total Holding Capacity, bu (m3)
205 + 95 = 300 (7.2 + 3.3 = 10.5)
275 + 125 = 400 (9.7 + 4.4 = 14.1)
345 + 155 = 500 (12.2 + 5.5 = 17.7)
415 + 185 = 600 (14.6 + 6.5 = 21.1)
485 + 215 = 700 (17.1 + 7.6 = 24.7)
Grain Column Thickness, (cm)
14β (35.6)
14β (35.6)
Avg / Max Operating Burner Capacity, MMBTU/hr (kW thermal)4
2.92 / 3.89 (856 / 1,140)
3.89 / 5.18 (1,140 / 1,518)
4.86 / 6.48 (1,424 / 1,899)
5.83 / 7.78 (1,709 / 2,280)
6.77 / 9.02 (1,984 / 2,643)
Capacity, Shelled Corn, 20%-15%5,6,7,8 wet bushels/hr (wet metric tonnes/hr) dry bushels/hr (dry metric tonnes/hr)
up to 575 (14.2) 550 (13.1)
up to 760 (18.8) 730 (17.4)
Avg / Max Operating Burner Capacity, MMBTU/hr (kW thermal)4
1.99 / 2.65 (583 / 777)
2.65 / 3.53 (777 / 1,035)
3.24 / 4.32 (950 / 1,266)
3.89 / 5.18 (1,140 / 1,518)
4.51 / 6.02 (1,322 / 1,765)
Capacity, Shelled Corn, 20%-15%5,7,8 wet bushels/hr (metric tonnes/hr) dry bushels/hr (metric tonnes/hr)
up to 330 (8.2) 310 (7.2)
up to 435 (10.8) 410 (9.6)
14β (35.6)
up to 945 (23.4) 910 (21.7)
up to 540 (13.4) 510 (11.9)