Each dryer model has a discharge capacity for every revolution of the metering rolls for profile dryers and sweep for tower dryers. These discharge capacities are used to calculate how much grain is being discharged from the dryer given a specific discharge speed. The chart below shows what these discharge capacities are in bushels per revolution and cubic meters per revolution.
Model(s) | bu/rev | m3/rev |
---|---|---|
L1000 - L6000
3.667
0.1292
D600 / D600h
2.433
0.0857
D900 / D900h - D2400 / D2400h
3.667
0.1292
D3200 / D3200h
4.889
0.1723
E300 / E300h
1.825
0.0643
E400 / E400h
2.433
0.0857
E500 / E500h
3.042
0.1072
E600 / E600h
3.667
0.1292
E700 / E700h
4.278
0.1507
10530
5.000
0.1786
10740
7.000
0.2500
10950
9.000
0.3214
101160
11.000
0.3929
101375
13.000
0.4643
12-20-100
10.000
0.35714
12-24-125
12.000
0.4286
12-28-150
14.000
0.4934
3000
40.000
1.4286
3500
45.000
1.6071
4000
50.000
1.7857
4800
55.000
1.9643