# Analog Inputs

The next selection at the bottom of the page is an I/O module, allowing up to 8 analog inputs.

<figure><img src="https://content.gitbook.com/content/QuAD4cJGmByvZ0oa7oPk/blobs/k7AgwABRqNJxF23wH62t/Screenshot%202024-10-09%20135717.png" alt=""><figcaption></figcaption></figure>

## 8 Analog Inputs

<table><thead><tr><th width="111">I/O</th><th width="148">Name</th><th>Description</th></tr></thead><tbody><tr><td>AI0</td><td>Inlet Moist</td><td>Indicates the moisture of the grain flowing across the infeed moisture sensor.</td></tr><tr><td>AI1</td><td>Inlet Temp</td><td>Indicates the temperature of the grain flowing across the infeed moisture sensor.</td></tr><tr><td>AI2</td><td>Outlet Moist</td><td>Indicates the moisture of the grain flowing across the discharge moisture sensor.</td></tr><tr><td>AI3</td><td>Outlet Temp</td><td>Indicates the temperature of the grain flowing across the discharge moisture sensor.</td></tr><tr><td>AI4</td><td>Burner #1 Temp </td><td>Indicates the plenum temperature from plenum 1 RTD.</td></tr><tr><td>AI5</td><td>Burner #2 Temp </td><td>Indicates the plenum temperature from plenum 2 RTD.</td></tr><tr><td>AI6</td><td>Burner #3 Temp</td><td>Indicates the plenum temperature from plenum 3 RTD.</td></tr><tr><td>AI7</td><td>Burner #4 Temp</td><td>Indicates the plenum temperature from plenum 4 RTD.</td></tr></tbody></table>