> For the complete documentation index, see [llms.txt](https://docs.mathewscompany.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.mathewscompany.com/dryer-operations/dryer-operations/operating-procedures/fireye-burner-control.md).

# Fireye Burner Control

{% hint style="info" %}
Fireye Burner Controls come standard on all product lines except Legacy Series.
{% endhint %}

All MicroM Programmer Modules have 5 LED lights to indicate the operating status of the control and also to display the coded sequence under locked out conditions. The function of the lights under a normal operating condition is:

## Operating Control

This LED is energized whenever the burner control switch and all other various limit switches are closed and power is applied to Terminal #7.

## Interlock or Air Flow

This LED is illuminated whenever power is detected on Terminal #6, indicating the air flow switch or other running interlock is closed. If the operating control is closed and the running interlock switch remains open, this LED will flash at a 1 second rate indefinitely for the MEP100 and MEP200 family. Lockout will occur if the switch remains open for 10 minutes in the MEP500 family. This LED will blink when configured as a flame switch and flame detected.

## PTFI

This LED is illuminated only during the pilot trial for ignition period and the stabilization period when so equipped.

## Flame

This LED is on whenever a flame signal is detected, and the control is not in a locked out state.

## Alarm

This LED flashes when an alarm condition is detected and is used as an address indicator (see communication).

During an alarm condition, the Alarm LED is made to flash at approximately a 1 second rate. The remaining four LEDs are illuminated as a coded sequence identifying the reason for the lockout. For instance, for a LOCKOUT - FLAME FAIL- PTFI, the INTERLOCK, PTFI and FLAME LED’s will all be lit steady, with the Alarm LED flashing. This remains true if power is removed and then restored in a locked out condition.

While in the Idle or Off state, the LEDs are made to flash sequentially to show the operational status of the control every minute. The LEDs can be tested by pressing and releasing the Reset push button, while in the Idle or Off state.

The table containing the list of lockout codes as well as the diagnostic messages and troubleshooting guide can be found below.

<figure><img src="https://3115024729-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FRYaukfq5nlgxjVPzEwDk%2Fuploads%2FgRXdxyYpUjKw06LR7evi%2FFireye%20Lockout%20Codes.png?alt=media&amp;token=c8573230-73b2-44e9-8846-11d384eb653c" alt=""><figcaption><p>Fireye Lockout Codes</p></figcaption></figure>

<figure><img src="https://3115024729-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FRYaukfq5nlgxjVPzEwDk%2Fuploads%2FnuzXz1MXdnhXsTrc1vIW%2FFireye%20Diagnostic%20Messages.png?alt=media&amp;token=d06551df-70a8-4140-bd14-4d3a01725414" alt=""><figcaption><p>Fireye Diagnostic Messages</p></figcaption></figure>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.mathewscompany.com/dryer-operations/dryer-operations/operating-procedures/fireye-burner-control.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.